Basic Info.

Model NO.:RTL-9200B
Display:Digital
Installation:Portable Precise
Accuracy:0.1
Kind:Rotating Coil
Power Source:AC Meter
Theory:Electric Apparatus
Application:Electronic Equipment
Display Ammeter Type:Single-phase Digital
Customized:Customized
Resolution: 0.01mA:Data Storage:99sets
Range: AC 0.0mA~1000A:Circuit Voltage: ≤ 60kv(Bare Wire 35kv)
Trademark:Refine
Specification:SGS
Origin:China
HS Code:90303110

Product Description

RTL-9200B Wireless H/L Voltage Clamp Current Meter has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopt latest CT technology and integrated mask digital technology, composed of special clamp current meter, wireless receiver and high voltage insulation rods. Wireless transmission can receive measured data within 30 meters line. Without insulation rods, it can used as high-precision low-voltage clamp meter and leakage current meter , can accurately measure the current or leakage current of 0.01mA.

RTL-9200B Wireless H/L Voltage Clamp Current Meter adopt hook type structure of innovation, which can hook the line to test, and through wireless transmission test date can save the physical power of user, to ensure the high precision , high stability and high reliability of perennial uninterrupted measurement.

The rods of RTL-9200 B Wireless H/L Voltage Clamp Current Meter can be used for insulating sheath wires ( ≤60kV ) and bare wire (≤35kV) high voltage line current measurement and online current measure below 60kV,also with the factions of peak value holding, data holding, data storage and wireless transmission , etc. It is easy to clamp or disconnect the wire by pulling-down or forwarding the insulation rods of the special clamp current meter, with the advantages of safely and time-saving. Widely used in power plant, substation industrial and mining enterprise, inspection station, electrician maintenance department for current sensing and field working. t can also be used as high and low voltage changing ratio tester , that is, respectively test the first loop and secondary loop high and low voltage change through manually calculation . The insulation rod is light and convenient, with the advantages of anti-moisture , high temperature resistance, anti-impact , bending resistance , high insulation , flexibility and other characteristics.



Technical Parameter
Model No.RTL-9200B
FunctionH-voltage AC current measure,L-voltage AC /leakage current measure, AC current monitor online
Power SupplyDC6V Alkaline Dry Battery(1.5V AAA × 4)
Test MethodClamp CT, Integral Method; hook the meter on the line to test, save the physical power of user.
Transmission methodwireless transmission, the maximum distance for direct transmission is about 30m.
Clamp Diameterφ68mm
Range of measurement0.00mA~1000A(50Hz/60Hz Automatic
Resolution0.01mA
Shift0.00mA~1000A Automatic Shift
Test Accuracy                                          (23ºC±5ºC,≤80%RH)0.00mA~299mA:    ±1%±3dgt 
0.30A~49.9A:        ±1.5%±5dgt 
50.0A~199.9A:      ±2%±5dgt
200A~600A:          ±3%±5dgt    
601A~1000A:         ±4%±5dgt   
Display Mode4 digital LCD display
LCD DimensionTester: LCD:35mm×21.5mm receiver LCD:47mm×28.5mm
Meter DimensionTester:218mm×135mm×60mm receiver:170mm×75mm×30mm
Sampling SpeedAbout 2 times/second
Data Storage99 Groups; during storage, the symbol "MEM" gives indication, "FULL" mark will flash to indicate the memory has been full.
PEAk MaintenanceAutomatically maintain the height of the test value,usually in the test mode press PEAK, LCD top right corner will display "PE",that is, to keep open the PEAK function, then press PEAK key to cancel this function key
Circuit VoltageTest insulating sheath wires (≤60kV) and bare wire (≤35kV) (operated with insulation rod)
Data PreservationUnder general test mode, press HOLD button to preserve data, "DH" symbol display. then press HOLD Key to cancel this function
Data Access"MR" symbol indicates, it can read the stored data by turning upwards and downwards.
Overflow DisplayExceed measurement range overflow function: "OL A" symbol display
Auto Shut DownAbout 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption.
Battery VoltageWhen the battery voltage is below 4.8V, the symbol of battery voltage"    "will show to remind to replace battery.
WeightTester:About 620g (Including battery)  receiver: about 220g(Including battery)
Total quality of meter: about 2.5kg(including insulation rod and battery)
Work Temperature and Humidity -10ºC~40ºC; ≤80%Rh
Storage Temperature and Humidity -10ºC~60ºC; ≤70%Rh
interferenceNo same frequency interference of 315MHz and 433MHz
Insulated Rod Dimensionφ32mm, 1m/ Section (5 Sections) 
Insulation IntensionTester: AC 2kV/rms(Between core and shell).                                                                                                  Insulation rod: AC 100kV/rms(5 sections insulating rod all connections, between both ends).
StructureAnti-Dripping Type II
AccessoriesTester:1set;  Receiver:1pcs;  Meter box:1pcs;  Insulation rod (1m): 5 Sections;                                          Battery: Alkaline Battery LR03): 8pcs
ModelRTL9200RTL9200B
Product ImageBitmap Bitmap
FunctionHigh voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement 
Power supplyDC6V Alkaline Battery (1.5V LR03×4)
Test ModeClamp CT,  integration mode; hook the meter on the line to test, save the physical power of user.
Transmission
Mode
/Wireless transmission, the maximum, distance of straight line transmission is about 30m
Clamp Size68mm
Range0.00mA~1000A (50Hz/60Hz automatically)
Meter
Dimension
Tester: 76×255×31(mm)Tester: 76×255×31(mm)
Receiver: 75×170×30(mm)
Resolution0.01mA
Range and Accuracy
(23ºC±5ºC Below 80%RH)
0.00mA~299mA:        ±1%±3dgt
0.30A~49.9A:            ±1.5%±5dgt
50.0A~199.9A:          ±2%±5dgt
200A~600A:              ±3%±5dgt
601A~1000A:            ±4%±5dgt
Display Mode4 Digital LCD display, Tester LCD: 35mmx21.5mm; Receiver LCD: 47mmx28.5mm
Meter DimensionTester: 218mmx135mmx60mm;Tester: 218mmx135mmx60mm;                      Receiver: 170mmx75mmx30mm
Sampling Rate2 times/second
Data Memory99 sets, memory process is shown by MEM , full storage is shown by blinking FULL
PEAK HoldingAutomatically maintain the height of the test value, usually in the test mode press PEAK key, LCD top right corner will display "PE", that is, to keep open the PEAK funtion, then press PEAK key to concel this fuction.
Circuit Voltage60KV(bare wire below35KV) (operated with 5 isolation rods)
Data HoldIn usual testing mode, press HOLD key to keep data, shown by HOLD, then press HOLD key to cancel this function
Data AccessMR indication, can access to all data
OverflowOver-range overflow function: shown in OL  A
No signal IndictionWhen the receiver has not received transit signal, it will display "no-- " Symbol
Auto power-offabout 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption.
Battery replaceWhen battery voltage is lower than 4.8V, it will indicate to replace the battery.
Meter Mass2.3kg (including insulation rod and battery)2.5kg (including insulation rod and battery)
Size of rodΦ32mm, 1m/piece (5 pieces)
Humiture - 10ºC ~ 40ºC; below 80%Rh
InterferenceNone 315MHz, 433MHz frequency interference
Insulation StrengthTester/receiver: AC 2kV/rms (Between core and shell); Insulation rod: AC 100kV/rms. (5 setions insulating rod all connections, between both ends)
AccessoriesMeter: 1pc, case: 1 pc
Rod: 5 pcs, battery(LR03):4pcs
Meter:1 pc receiver:1 pc
Case: 1 pc, rod:5pc
Battery(LR03):8pc,


Send your message to this supplier
Avatar
Mr. Zhou
Manager
*From
To Mr. Zhou
*Message
Enter between 20 to 4,000 characters.
This is not what you are looking for? Post a Sourcing Request Now

Refine Technology Limited

- Guangdong, China
- Manufacturer/Factory

Gold Member Since 2012
Audited Supplier
  • Sample Available
  • OEM/ODM Service
  • Spanish Speaker